|
Product Description
Many diabetics may have some questions when using a blood glucose meter.Why the test reading got from home blood glucose meter different from the test results got from hospital?
Most glucose meters are well designed and give reasonably accurate test results. It is not like lab equipment but it still has its own ISO standard (ISO 15197) to follow. Blood glucose meters are considered clinically accurate if the result is within ±15mg/dL (<100 mg/dL) or ±15% (≧100 mg/dL) of what a lab test would indicate.
For example, if your glucose meter result (whole blood) was 200 mg/dL, and the lab test result (plasma) was 230 mg/dL, the difference % will be (whole blood glucose value - plasma blood glucose value) / plasma*100, the result will be (200-230)/230*100=-13%, which has met the ISO 15197 standard.
Why were results different after measuring blood sugar twice in a row?
For example: I used the portable blood glucose meter to check the blood sugar before having my breakfast, the first result was 270 mg/dL, and I tested it again immediately; however, the second one was 230 mg/dL. Which one was correct?
In fact, both of the results were pretty high. You got 2 different results because of your blood circulation and the sugar mixed into the blood. You might test a blood drop with your meter that has more glucose; you might test next blood drop that contains less glucose. Both reflected in your 2 different blood glucose checks. Basically, there is an about 5% difference when using the same blood sample but both are accurate.
Why the results measured by different companies' blood glucose meters are different?
The test results for the same blood sample may vary because each manufacturer's blood glucose meter setting is different,. Therefore, it is not recommended to compare different brands of blood glucose meters.
Features
- TEST STRIPS FOR USE WITH DS-W METER. The manufacturing of AUVON blood sugar test strips uses automatic carbon printing technique, which ensures that the quality of each batch of strips could be relevantly much more stable and accurate.
- CUTTING-EDGE TEST STRIPS. We use cutting-edge test strips enzymes for blood glucose measurements. Our test strips are produced with unique Automatic Carbon Printing Technique to ensure that the quality of each batch of strips could be relevantly much more stable, precise and accurate.
- SYPHONAGE AUTO BLOODINGSUKING. Top-side syphon application window ensures that the blood sample can go directly to the testing area, making test results more accurate and stable.
- NO CODING REQUIRED. No Coding Technology remove the worry of inaccurate results from a miscode, giving you one less thing to think about when managing your diabetes.
- WHAT YOU RECEIVE: 150 x Blood Glucometer Test Strips, 1 x Test Strip User Guide, lifetime technical support and friendly customer service. (For use with AUVON DS-W Meter only)
Customers Who Bought This Item Also Bought
- AUVON DS-W Blood Sugar Kit (No Coding Required), High-Tech Diabetes Blood Glucose Meter with 50 Test Strips, 50 30G Lancets, Lancing Device
- AUVON DS-W Blood Sugar Kit (No Coding Required), High-Tech Diabetes Blood Glucose Meter with 150 Test Strips, 25 30G Lancets, Lancing Device
- ijCare 30g Lancets for Blood Testing (300pcs) - Fits Any Standard Lancet Devices, and Diabetic Lancing Device in Our Blood Sugar Test Kit, Affordable Diabetic Supplies/Finger Pricker (3)
- Contour Next Microlet Lancing Device, 3 Count + O'WELL Lancets, 300 Count (30 Gauge)
- AUVON Blood Lancets, 30 Gauge 100 Twist Top Lancets with Less Pain Design Fit Most Standard Lancing Devices for Blood Sugar Kit and Glucose Meter
- AUVON DS-W Blood Sugar Kit (No Coding Required), High-Tech Diabetes Blood Glucose Meter with 100 Test Strips, 25 30G Lancets, Lancing Device
- AUVON DS-W Blood Sugar Test Kit (100 Test Strips, 100 30G Lancets), High-Tech Diabetes Blood Glucose Meter (No Coding Required) with Lancing Device
- AUVON Blood Glucose Test Strips (100 Count) for use with AUVON DS-W Diabetes Sugar Testing Meter (No Coding Required, 2 Box of 50 Each)
- AUVON Lancing Device with Less Pain Design, Blood Sample Pen and Twist Top 100pcs 30 Gauge Lancets for Blood Sugar Level Monitoring and Glucose Testing
- AUVON Blood Glucose Test Strips (50 Count) for use with AUVON DS-W Diabetes Sugar Testing Meter (No Coding Required, 2 Box of 25 Each)
*If this is not the "AUVON Blood Glucose Test Strips (150 Count) for use with AUVON DS-W Diabetes Sugar Testing Meter (No" product you were looking for, you can check the other results by clicking this link. Details were last updated on Dec 20, 2024 02:24 +08.